ZQ80 IBM Machine | 800 kN, European Structure

ZQ80 IBM machine with 800 kN clamping — 18% above Jomar IBM85S. 466 g shot weight, 20-cavity at 10 ml, 2.0 m machine height. Full European frame. Ships to Canada. Request factory pricing.

分类:

描述

ZI-QIANG · ZQ Series IBM Machine

ZQ80 IBM Machine — 800 kN Clamping Force,
Full European Frame, 20-Cavity at 10 ml

The ZQ80 IBM machine is a one-station, three-position injection blow molding machine built on a full European-style frame with an 800 kN injection clamping force. Injection, blow molding, and ejection run in a single uninterrupted cycle, producing flash-free, dimensionally consistent hollow containers from 10 ml to 2,000 mm bottle height with no post-trim step at any stage. With a 4-second dry cycle, a 55 mm screw delivering 466 g shot weight, and a total installed power of 55 kW running at 52%–70% operating load, the ZQ80 IBM Canada-compatible machine is built for multi-shift pharmaceutical, cosmetic, food-grade, and laboratory packaging operations.

The ZQ80 processes PP, HDPE, LDPE, PET, PC, PS, SAN, PMMA, and PETG through a single 55 mm screw with a 22:1 L/D ratio and 4 + N barrel heating zones (11 kW). The 800 × 400 mm platen supports up to 20 cavities on 10 ml formats, scaling to 3–4 cavities at 1,000 ml. The machine stands 2.0 m tall — fitting under standard Canadian industrial ceiling heights without structural modification, and ships with English documentation and export crating as standard.

ZQ80 IBM Machine

800
kN Clamp Force
466
g Shot Weight
20
Cavities @ 10 ml
4 s
Dry Cycle
2.0 m
Machine Height

Key Features of the ZQ80 IBM Machine

Clamping Force

800 kN — Highest in This Comparison Class

The ZQ80 delivers 800 kN at the injection station, ahead of all three published reference models: Jomar IBM85S at 680 kN (+18%), BLOMA IBM85 at 700 kN (+14%), and SUMA 85iB at 720 kN (+11%). Higher clamping force maintains platen parallelism under injection pressure, keeps flash generation consistent, and extends mould service intervals without mid-run pressure adjustments.

Frame Construction

Full European-Style Frame — Not Selectively Adopted

The clamping system, tie-bar geometry, and platen assembly all conform to European structural standards throughout. Machines running 24-hour pharmaceutical cycles accumulate hundreds of millions of clamping events annually — frame rigidity under thermal cycling determines whether part tolerances hold across shifts, not just at startup.

Indexing System

High-Precision Angle Divider — Synchronised Open, Close, and Turret Lift

The ZQ80 uses a high-precision angle divider that mechanically synchronises mould opening, closing, and turret lifting in one coordinated movement — reducing independent actuations per cycle, lowering cumulative positioning error, and eliminating the periodic recalibration that servo encoder systems require. For pharmaceutical operations where indexed position accuracy directly affects neck flash and thread concentricity, this is a maintainability advantage.

Energy System

Hydraulic Dual-System — Booster Decoupled, 20%–30% Lower Energy Draw

The booster cylinder activates only at the clamping phase — the mould open/close stroke runs on the main cylinder alone. A hydraulic dual-system is standard, managing injection and blow stations on independent circuits. Operating power runs at 52%–70% of the 55 kW installed total, a 20%–30% reduction versus conventional full-stroke booster designs. At Ontario industrial electricity rates, this is a calculable per-shift saving.

Shot Capacity

466 g Shot Weight — 55% Above the Jomar IBM85S

A single 55 mm screw with 22:1 L/D and 180 mm stroke delivers 466 g per shot. Against the Jomar IBM85S (300 g), that is 55% higher shot capacity on the same screw diameter. Against the BLOMA IBM85 (310 g), the ZQ80 delivers 50%+ more. This expands the range of container sizes and resins the machine covers without a screw change — including 500 ml to 1,000 ml formats in a single cycle.

Platen & Cavity

800 × 400 mm Platen — Up to 20 Cavities at 10 ml

The 800 × 400 mm platen supports 20 cavities at 10 ml, 18 at 30 ml, 14 at 60 ml, and 12 at 100 ml. At 4 seconds dry cycle, a 12-cavity 100 ml configuration yields a theoretical 10,800 bottles/hour under continuous production — throughput rates relevant to high-volume pharmaceutical vial and cosmetic sample-bottle lines served by IBM machines in Canada.

Installation Footprint

2.0 m Machine Height — Lowest in This Comparison Class

The ZQ80 stands 2.0 m tall — versus 3.41 m for the Jomar IBM85S, 2.6 m for the SUMA 85iB, and ~2.55 m for the BLOMA IBM85. A 2.0 m machine installs under a standard 2.4 m suspended industrial ceiling with no structural modification — a hard constraint in many Canadian pharmaceutical cleanrooms and food-grade packaging facilities in Ontario and Quebec.

Process Efficiency

Zero-Scrap Neck Formation on Every Cycle

The IBM process forms the full neck geometry — threads, plug-seal lands, tamper bands — in the injection station. No flash trimming, no regrind stream. For Canadian food-grade and pharmaceutical lines where GMP compliance requires material traceability documentation, zero scrap also simplifies batch record management across high-cavity, multi-shift runs.

Key Features of the ZQ80 IBM Machine

ZQ80 Full Technical Specifications

范围 Unit ZQ80
Injection System
螺纹直径 mm 55
Screw L/D Ratio 22:1
Injection Weight g 466
加热功率 kW 11
Number of Barrel Zones 4 + N
Injection Stroke mm 180
Clamping System
注射夹紧力 kN 800
Opening Stroke (Injection) mm 140
Blow Clamping Force kN 120
Opening Stroke (Blowing) mm 140
Rotary Table Lifting Height mm 70
Mould
Max. Platen Size (L × W) mm 800 × 400
Mould Thickness mm 280
Max. Bottle Diameter mm 120
Max. Bottle Height mm 220
Suitable Bottle Height Range mm 1 – 2,000
Stripping Stroke mm 230
Hydraulic System
Hydraulic Pressure MPa 14
Motor Power (dual) kW 18.5 + 18.5
Dry Cycle s 4
Total Power kW 55
Operating Power % 52 – 70
Others
Min. Compressed Air Pressure MPa 0.8 – 1.2
Compressed Air Capacity m³/min 0.8
Water Flowage m³/h 4
冷却水压力 MPa 0.3 – 0.4
Machine Dimensions (L × W × H) m 4.5 × 1.6 × 2.0
Net Weight Ton 10

ZQ80 vs. Comparable IBM Machines

Third-party models listed for buyer reference and model selection only. ZI-QIANG does not manufacture or sell any third-party equipment. All brand names are trademarks of their respective owners.

ZQ80 · ZI-QIANG

Clamp Force800 kN
Injection Weight466 g
螺纹直径55 mm
Platen Size800×400 mm
Height2.0 m

IBM85S · Jomar · USA

Clamp Force680 kN −15%
Injection Weight300 g −36%
螺纹直径55 mm
Platen Size464×749 mm
Height3.41 m

ZQ80 · ZI-QIANG

Clamp Force800 kN
Injection Weight466 g
螺纹直径55 mm
Platen Size800×400 mm
Height2.0 m

85iB · SUMA · Taiwan

Clamp Force720 kN −10%
Injection Weight333–480 g
螺纹直径50 / 60 mm
Platen Size700×400 mm
Height2.6 m

ZQ80 · ZI-QIANG

Clamp Force800 kN
Injection Weight466 g
螺纹直径55 mm
Platen Size800×400 mm
Height2.0 m

IBM85 · BLOMA · Korea

Clamp Force700 kN −13%
Injection Weight310 / 280 g −33–40%
螺纹直径50 mm
Platen Size620×430 mm
Height~2.55 m

* Third-party data from publicly available technical documentation. Verify current specs with respective manufacturers.

ZQ80 Mould Cavity Reference

For reference only — actual cavitation depends on container geometry, wall thickness, and resin.

Volume 10 ml 30 ml 60 ml 100 ml 250 ml 500 ml 1,000 ml
Max. Cavities 20 18 14 12 8 5–6 3–4

Industries the ZQ80 IBM Machine Serves in Canada

The ZQ80 targets B2B packaging manufacturers, pharmaceutical contract packagers, and food-grade container operations running two or three shifts on formats between 10 ml and 1,000 ml. It ships to buyers across Ontario, Quebec, British Columbia, and Alberta with English documentation, export crating, and CE-compatible electrical specs as standard. For Canadian operations sourcing an IBM machine Canada alternative — whether replacing an ageing Jomar IBM85S or establishing a new line — the ZQ80 provides a documented specification baseline with factory pricing available on request.

Pharmaceutical Packaging

Oral liquid bottles, eye-drop vials, tablet containers, and nasal spray bottles in PP or HDPE. At 20 cavities × 10 ml and 4-second dry cycle: up to 18,000 vials/hour theoretically. Neck threads and plug-seal geometry formed in the injection station — directly supporting GMP batch traceability under Health Canada guidelines.

Cosmetics & Personal Care

Perfume vials, pump-top lotion dispensers, roll-on deodorant containers in SAN, PMMA, or transparent PET. Wall thickness distribution set at the preform stage for consistent optical clarity across all cavities. Relevant to Canadian cosmetic brands in BC and Ontario sourcing injection blow molding machines for cosmetic packaging at this cavitation level.

Food & Beverage

Condiment jars, honey dispensers, syrup bottles in PP or HDPE under CFIA-compliant food-grade production. Zero neck scrap on every cycle eliminates regrind stream management — simplifying material traceability and floor hygiene on Canadian food processing lines.

Lab & Medical Ware

Wash bottles, specimen jars, laboratory flasks 250 ml–1,000 ml in PC or PETG. The 466 g shot weight covers 1,000 ml formats in a single cycle that the Jomar IBM85S (300 g) cannot reach, making the ZQ80 a more direct fit for mid-volume laboratory ware lines evaluating an ibm machine for laboratory container manufacturing.

Frequently Asked Questions — ZQ80 IBM Machine

Q1 — How does the ZQ80 compare to the Jomar IBM85S on clamping force and shot weight?

The ZQ80 delivers 800 kN vs the Jomar IBM85S‘s 680 kN (+18%). On shot weight: 466 g vs 300 g (+55%) using the same 55 mm screw diameter. The ZQ80 covers 500 ml–1,000 ml containers in a single shot that the IBM85S cannot reach at standard configuration — without a screw change.

Q2 — Can the ZQ80 replace a Jomar IBM85S or SUMA 85iB currently in production?

In most cases yes, subject to mould fitment review. The ZQ80’s 800 × 400 mm platen is comparable in area to the SUMA 85iB‘s 700 × 400 mm. Moulds for those platforms may need minor dimensional adaptation. Share your current mould drawings at enquiry stage and we confirm fitment before order placement — standard practice for all IBM machine Canada replacement projects.

Q3 — What does the angle divider do differently from a servo rotation system?

A servo system uses an independent motor and encoder to index the turret. The ZQ80’s angle divider mechanically links turret lifting to the mould open/close movement in one coordinated actuation — removing one independent actuator, reducing cumulative positioning error, and eliminating the periodic encoder recalibration servo systems require. For pharmaceutical operations where indexed position accuracy affects neck flash and thread concentricity, this is a maintainability and consistency advantage.

Q4 — What is the actual energy draw in production?

The decoupled booster and hydraulic dual-circuit design means the ZQ80 runs at 52%–70% of its 55 kW installed capacity — effectively 28–38 kW during production. At Ontario’s industrial electricity rate of approximately CAD 0.09–0.12/kWh (2025 ICI tariff), this is a calculable per-shift saving versus a conventional full-load 55 kW design. The dual 18.5 kW motors also allow one circuit to continue running during minor maintenance on the other, reducing unplanned downtime.

Q5 — What hourly output on a 100 ml pharmaceutical bottle line?

12 cavities × 4-second dry cycle = theoretical 10,800 bottles/hour. Actual total cycle for 100 ml PP pharmaceutical formats typically runs 5–8 seconds including cooling, yielding 5,400–8,640 bottles/hour at 12 cavities. Contact us with your bottle drawing and resin spec for a validated cycle time estimate.

Q6 — Does the ZQ80 meet Canadian cleanroom installation requirements?

At 2.0 m tall, the ZQ80 fits within standard ISO Class 7/8 cleanroom bay heights (typically 2.4 m suspended ceiling) without structural modification — unlike the Jomar IBM85S at 3.41 m. Zero neck scrap eliminates trimming-related particulate risk. English documentation, CE-compatible electrical spec, and FAT reports are available on request for Health Canada GMP validation submissions.

Q7 — Do you ship to buyers in Ontario, Quebec, and British Columbia?

Yes. We export the ZQ80 directly to Canadian buyers across Ontario, Quebec, BC, and Alberta. As an established injection blow molding machine manufacturer with direct export history to North America and Europe, we provide export documentation, commercial invoice, packing list, and Bill of Lading for CIF or FOB shipment to Canadian ports. Lead time and Incoterms confirmed at order stage.

Ready to Source the ZQ80?

Request ZQ80 IBM Machine Specifications and Factory Pricing

Share your container volume, resin, target cavitation, and shift plan. Our engineering team responds within 2 business days with a matched ZQ80 configuration, cavity reference data, and a commercial proposal. Comparing against Jomar IBM85S, SUMA 85iB, Uniloy UIB120, or BLOMA IBM85? We supply a direct spec comparison on request. Canadian buyers in Ontario, Quebec, and BC welcome.

Get a Quote for the ZQ80

其他信息

editor

wm